Everything you would otherwise have to learn by getting a post removed. Chromatograms, methods, integration. Bring the raw trace.
wiki page · last revised 16 Jul 2026 · maintained by community volunteers
On this page
What this community is for
The analytical deep end: RP-HPLC methods, gradient design, integration decisions, LC-MS confirmation, amino-acid analysis, water content, and why two labs can report 98.1% and 96.4% on the same vial and both be right. Post the chromatogram, not the summary line.
c/hplc was created on 14 Sep 2023 and currently has 31,700 members and 130 captured submissions. It sits in the busiest tier of the site, which mostly affects how fast a question gets answered rather than how well.
The one-line version
Chromatograms, methods, integration. Bring the raw trace.
Rules, and why each exists
Community rules come first, then the six site-wide rules that apply everywhere on GLP Research Hub. Community rules are enforced by the moderators listed at the bottom of this page; site rules are enforced by everyone.
- Chromatogram or it did not happen. Axis labels included.
- State the method: column, gradient, detection wavelength, injection volume.
- Area% is not mass%. Posts that conflate them get a correction flair, not a removal.
And the site rules, which are short on purpose:
- Independent community. Nobody here sells anything, and anyone who tries is banned.
- Not medical advice. Describe what you did; never prescribe to a stranger.
- Claims need evidence. Batch numbers, dated screenshots, independent test reports, or a citation.
- No referral links, discount codes or affiliate URLs. Permanent ban, no appeal.
- No contact handles, wallet addresses or tracking numbers — they identify people.
- Be recognisably decent. Disagree hard, insult nobody.
Terms you will see
Vocabulary that turns up constantly in c/hplc. Each links to the topic page, which collects every submission that touches it.
- HPLC — high-performance liquid chromatography — the workhorse separation method here.
- chromatogram — the raw detector trace. Post it; the summary line hides the interesting parts.
- gradient — the changing mobile-phase composition that separates the peaks.
- LC-MS — chromatography plus mass spectrometry; the method that answers identity.
- integration — deciding where each peak starts and stops — where a lot of the number comes from.
- purity — usually area% from a UV chromatogram: how much of what the detector saw was product.
- method development — building a separation that resolves what you care about.
Start here
The twelve highest-scoring submissions in this community. Not necessarily the most correct — the most agreed-with, which is a different thing, and worth remembering when you read them.
- [Lab] split one vial across PeptideMeter and VendorInvestigate — 93.7% and 94.2% — 15k points, 39 comments, 2 years ago
- [Lab] QSC cagri — Janoshik came back 98.6% against a claimed 98.5% — 14k points, 36 comments, 2 years ago
- does chromatogram actually matter or is it forum lore at this point — 14k points, 44 comments, 2 years ago
- [Lab] 18th independent test on SWB — 99.4% on a claimed 99.0%, and the trend is the interesting part — 12k points, 58 comments, 2 years ago
- [Lab] WXT cagri — PeptideMeter came back 97.8% against a claimed 97.0% — 12k points, 49 comments, 1 year ago
- integration is the most under-discussed thing on this board — 12k points, 18 comments, 2 years ago
- [Lab] MKM cagri — Medutest came back 97.2% against a claimed 97.0% — 11k points, 64 comments, 1 year ago
- help me understand method development, I have read the wiki twice — 10k points, 46 comments, 2 years ago
- [Question] how do you actually verify gradient — 9.5k points, 14 comments, 2 years ago
- [Question] is 94.2% actually fine or am I being sold a rounding error — 8.8k points, 31 comments, 2 years ago
- [Lab] split one vial across PeptideMeter and VendorInvestigate — 96.8% and 99.1% — 8.6k points, 48 comments, 1 year ago
- [Lab] ERP cagri — PeptideMeter came back 98.8% against a claimed 98.0% — 8.4k points, 28 comments, 2 years ago
Asked constantly
- two labs, same vial, 98.1 and 96.4. both right?
- peak at 4.2 min, nobody can tell me what it is, ideas
- two labs, same vial, 98.1 and 96.4. both right?
- [Question] what is a reasonable system suitability RSD for this work
- reading integration threads from 2024 and half of it aged badly
- [Question] HPLC — what am I missing here
- genuine question about purity that I am slightly embarrassed to ask
- [PSA] HPLC is not what most of this community thinks it is
- [PSA] chromatogram is not what most of this community thinks it is
- [Question] how do you actually verify LC-MS
If your question is on that list, read the answers there first. If it is not, ask it — that is what the community is for, and "this has been asked" is only a helpful reply when it comes with a link.
Who runs this
Moderation here is done by volunteers who also post as normal members. They are not clinicians, not vendors, and not paid.
- u/sig_figs_sam — c/hplc mod. Analytical chemist by trade. Round your numbers responsibly.
- u/hplc_hobbyist — Bought a second-hand HPLC and a lifetime of regret. I post chromatograms, not conclusions.
- u/peak_area_pete — Area% is not mass%. I will keep saying this until the sun goes out.
- u/mass_spec_maggie — LC-MS/MS is my day job. Peptide mapping is my hobby. Both are the same job.