comment on [Correction] you cannot report area% to two decimals off that baseline in c/hplc · 2 points · 6 days ago

reproducibility beats resolution if you only get one of them

permalink

comment on two labs, same vial, 98.1 and 96.4. both right? in c/hplc · 160 points · 7 days ago

UV response is not uniform across species. At 214nm you are looking at the peptide bond, which is why it is the working wavelength for this class; at 280nm you only see tryptophan, tyrosine and phenylalanine.

permalink

comment on [Lab] LC-MS confirmed identity but the UV purity is 94%. now what in c/hplc · 3 points · 16 days ago

ghost peak, check the plumbing first, it is always the plumbing

permalink

comment on everyone here has a spreadsheet, do i need a spreadsheet in c/newbiequestions · 14 points · 24 days ago

write the concentration on the vial, you will thank yourself

permalink

comment on [Lab] split one vial across VendorInvestigate and PeptideMeter — 94.2% and 93.7% in c/hplc · 105 points · 1 months ago

Careful — you are treating retention time as identity. Two things can co-elute and the trace will not tell you.

permalink

comment on help me understand gradient, I have read the wiki twice in c/hplc · 133 points · 2 months ago

area percent is relative to what the detector saw and nothing else

permalink

comment on someone explain purity to me like I have not read a paper in years in c/hplc · 283 points · 2 months ago

System suitability — repeat injections, tailing factor, plate count, RSD on area — is what tells you the instrument was fit for the measurement that day. Without it, the purity figure is unanchored.

permalink

comment on anyone else notice first time kicking in around week 66 in c/newbiequestions · 8 points · 2 months ago

Pen or vial?

permalink

comment on [Discussion] we are measuring method development at the wrong time and calling it noise in c/hplc · 82 points · 4 months ago

That is area percent, not mass percent. The trace cannot give you the second one.

permalink

comment on three years of HPLC threads, summarised so you do not have to read them in c/hplc · 7 points · 5 months ago

Same view — reporting the gradient is what makes a result checkable rather than merely stated.

andres_restrepo is right — the integration choice is a decision and it should be stated alongside the result.

permalink

comment on genuine question about chromatogram that I am slightly embarrassed to ask in c/hplc · 0 points · 5 months ago

Can you post the trace with the axes labelled?

permalink

comment on normal: the version I wish someone had shown me in week 1 in c/newbiequestions · 90 points · 6 months ago

Bacteriostatic water contains a preservative, which is what makes repeated entry into a vial reasonable. Sterile water does not, and the two are not interchangeable for that purpose.

permalink

comment on [Question] gradient — what am I missing here in c/hplc · 89 points · 7 months ago

baseline choice is a decision, not a measurement

permalink

comment on [Question] gradient — what am I missing here in c/hplc · 80 points · 7 months ago

What wavelength, and what was the gradient?

permalink

comment on [Question] gradient — what am I missing here in c/hplc · -32 points · 7 months ago

Area percent is the integrated area of your peak over the total integrated area at one wavelength on one gradient.

Disagreeing with this bit: that spread is ordinary inter-lab variance, not a disagreement about the material.

permalink

comment on [Meta] proposal — a flair for chromatogram posts in c/hplc · 2 points · 7 months ago

you cannot report to two decimals off that baseline

permalink

comment on [Discussion] we are measuring HPLC at the wrong time and calling it noise in c/hplc · 116 points · 8 months ago

That is area percent, not mass percent. The trace cannot give you the second one.

permalink

comment on [Question] beginner — what am I missing here in c/newbiequestions · 4 points · 11 months ago

Correction: the starting dose is a tolerance step rather than a treatment dose. The distinction is the answer to the question above.

permalink

comment on switched from 1.0mg to 2.4mg and sulphur burps got better, not worse in c/newbiequestions · 61 points · 1 year ago

What week are you in?

permalink

comment on switched from 1.0mg to 2.4mg and sulphur burps got better, not worse in c/newbiequestions · 74 points · 1 year ago

Flair set to Question and the wiki page linked in a comment rather than in place of an answer.

Adding the one habit worth starting today: write the concentration on the vial.

permalink

comment on switched from 1.0mg to 2.4mg and sulphur burps got better, not worse in c/newbiequestions · 130 points · 1 year ago

Is this your first step up or the starting dose?

permalink

comment on three years of gradient threads, summarised so you do not have to read them in c/hplc · 84 points · 1 year ago

That figure cannot be quoted to two decimals off that baseline. The precision is not in the data.

permalink

comment on [Question] how do you actually verify HPLC in c/hplc · 4 points · 1 year ago

Same method at both labs, or two different gradients?

permalink

comment on [Question] is 98.1% actually fine or am I being sold a rounding error in c/hplc · 43 points · 1 year ago

Disagree. Inter-lab spread of a point or two on this assay is ordinary and calling it a discrepancy misleads people.

permalink

comment on switched from 0.25mg to 2.4mg and reflux got better, not worse in c/newbiequestions · 23 points · 1 year ago

research-use-only material is not approved for human use, and that belongs in every beginner thread

permalink

comment on [Lab] split one vial across Janoshik and Medutest — 98.7% and 98.3% in c/hplc · 14 points · 1 year ago

That is area percent, not mass percent. The trace cannot give you the second one.

permalink

comment on beginner is the most under-discussed thing on this board in c/newbiequestions · -4 points · 1 year ago

Took three weeks to understand titration and about ten seconds once somebody explained it as a tolerance ladder.

permalink

comment on [Meta] the chromatogram rule is doing its job and people should stop complaining in c/hplc · 67 points · 1 year ago

UV response is not uniform across species. At 214nm you are looking at the peptide bond, which is why it is the working wavelength for this class; at 280nm you only see tryptophan, tyrosine and phenylalanine.

permalink

comment on genuine question about HPLC that I am slightly embarrassed to ask in c/hplc · 1 points · 1 year ago

214nm sees the peptide bond, 280nm sees the aromatics

permalink

comment on [Results] 16 weeks, 5kg, and basics were the hard part in c/newbiequestions · 333 points · 1 year ago

Asked what a COA was in my first week. Somebody linked the explainer and I have been reading them ever since.

permalink

comment on is it normal to get constipation at week 11 in c/newbiequestions · 1 points · 1 year ago

I would not panic about that. It is on the list of ordinary first-month experiences.

permalink

comment on [Discussion] the gradient advice in here is 3 years out of date in c/hplc · 3 points · 2 years ago

Sent the same vial to PeptideMeter and Medutest. 98.7% against a claimed 98.5%. The difference was the gradient, not the material.

permalink

comment on help me understand basics, I have read the wiki twice in c/newbiequestions · 1 points · 2 years ago

nobody here can tell you what dose to be on

permalink

comment on am I the only one who found first time harder than the injections in c/newbiequestions · 359 points · 2 years ago

read the wiki first, then ask anyway

permalink

comment on [Lab] KP cagri — VendorInvestigate came back 98.1% against a claimed 97.5% in c/hplc · 143 points · 2 years ago

Careful — you are treating retention time as identity. Two things can co-elute and the trace will not tell you.

permalink

comment on [Lab] 18th independent test on SWB — 99.4% on a claimed 99.0%, and the trend is the interesting part in c/hplc · 66 points · 2 years ago

System suitability — repeat injections, tailing factor, plate count, RSD on area — is what tells you the instrument was fit for the measurement that d

This is the whole methodological point of the board in one line.

permalink

Trophy case

No trophies yet. Most accounts here never get one.

Cake day 14 May 2025
Sponsored

Sigma-Aldrich Standards

Certified reference materials for peptide identity and purity work.

sigmaaldrich.com
Where they post
Before you read on

Several compounds discussed on GLP Research Hub are sold for research use only and are not approved for human use anywhere. Nothing here is medical advice and none of it is written by your clinician. If a post reads like an instruction, treat it as a description of what one stranger did.